1. Home
  2. Autos
  3. Auto Repair

Diagnosing GM Converter Lock-Up Problems

From Vincent Ciulla, About.com Guide

Diagnosing GM Converter Lock-Up Problems

Test #6 (Regular Method)

   Check for ground at terminal D at the transmission.

  1. On Non-computer-controlled vehicles skip this test and go directly to cooler line pressure, or surge test.
  2. Raise the vehicle on the lift so the driving wheels are off the ground.
  3. Unplug the wires at the case and connect the alligator clip of your test light to terminal A.
  4. Place the tip of your test light on terminal D.
  5. Start the engine and bring to normal operating temperature.
  6. Place the selector in Drive. (O.D. on four speed units).
  7. Accelerate slowly to 60 mph and the tester should light.
  8. If the tester does not light you have a computer system problem. Go to test # 7 (Regular Method).

Test #6 (Quick Method)

   Check for ground at terminal D at the ALDL

Note: First you must have passed ALDL Quick method (Test # 1. Otherwise continue with regular method Test # 6).
  1. The test light should still be connected between terminal A and F at the ALDL.
  2. With the engine at normal operating temperature, go for a road test
  3. As you start your road test the tester should be lit.

    Note: If your foot is on the brake the light will be out.

  4. Watch the test light to see if it goes out at some point during the road test
  5. If the test light goes out, you have ground at terminal D at the transmission. Go to test # 7.
  6. If the test light stays on you have a computer system problem. (See test # 13) Go test # 7.

Test #7 (Regular Method)

   Ground the D wire at the transmission

  1. Shave a little insulation from or pierce the D wire near the transmission connector. Reseal with silicon.
  2. Connect one end of a jumper wire to the bare wire you just shaved or pierced.
  3. Connect the other end of the jumper wire to ground.
  4. Road test for lock-up (can be done on lift).
  5. If you're not sure if lock-up occurred, then hold a steady speed of 60 mph (on the lift) and lightly touch and release the brake. You should feel lock-up disengage and re-engage.

Test #7 (Quick Method)

   Ground the D wire at the ALDL

Note: You must first have passed ALDL Quick method (Test # 1).

  1. Connect one end of a test light or jumper wire to terminal A at the ALDL.
  2. Go for a road test. (This can also be done on the lift)
  3. At approximately 35 mph, connect the other end of the test light or jumper wire to terminal F at the ALDL. The torque converter should Lock-up.
  4. Whether the T/C locks up or not, follow the trouble-shooting tree to the next step, cooler line surge test.

Test #8

   Checking Cooler Line Pressure or Surge

  1. Check cooler line pressure or surge.
  2. Disconnect a cooler line.
  3. Attach one end of a rubber hose to the disconnected line coming from the radiator.
  4. Insert the other end of the rubber hose into the fill tube of the transmission.
  5. With the driving wheels off the ground, start the engine. Hold the rubber hose in your hand. Have as assistant place the selector in Drive and (slowly) accelerate to 60 mph. When the lock-up valve moves, the rubber hose should jump slightly.

Test #9

   Checking the Solenoid

You will need an ANALOG ohmmeter and a 12-volt source for this test.

  1. Connect the Black lead of your ohmmeter to the RED wire on the solenoid.
  2. Connect the RED lead of your ohmmeter to the BLACK wire on the solenoid. If you have a one-wire solenoid then connect the RED lead of your ohmmeter to the solenoid body.
  3. With the ohmmeter set at ohms times one (Rx1), the reading should be no less then 20 ohms, but not infinite.
  4. Connect the RED lead of your ohmmeter to the RED wire on the solenoid and the Black lead to the Black wire or body (You're just switching your connections).
  5. The ohmmeter should read less than the reading in the first test.
  6. Connect the solenoid to a 12-volt source. BE SURE TO OBSERVE PROPER POLARITY, if using a car battery.
  7. With lung pressure (or very low pressure) try to blow through the solenoid. It should be sealed.
  8. Disconnect the 12-volt source and you should now be able to blow through the solenoid.

Test #10

   Checking Electrical Switches on Transmission

Note: If you have passed the ALDL Quick methods, the electrical switches are NOT causing the any lock-up condition. Go to test # 11.

SWITCH TYPE: Single terminal normally open
PART#: 8642473
TEST: Connect one ohmmeter lead to the terminal of the switch and the other lead to the body of the switch. Ohmmeter should read infinite. Apply 60 psi of air to the switch and the ohmmeter should read 0.

SWITCH TYPE: Signal terminal normally closed
PART#: 8642569, 8634475
TEST: Connect one ohmmeter lead to the terminal of the switch and the other lead to the body of the switch. Ohmmeter should read 0. Apply 60 psi of air to the switch and the ohmmeter should read infinite.

   Copyright © 2001 - 2003 Vincent T. Ciulla All Rights Reserved

Explore Auto Repair
About.com Special Features

Stay safe and save time by following these tips before driving a used car. More >

Discover the hottest cars for the 2010 calendar year. More >

  1. Home
  2. Autos
  3. Auto Repair

©2009 About.com, a part of The New York Times Company.

All rights reserved.